C1116
DTC C1116 STOP LAMP SWINSPECTION PROCEDURE
1.CHECK SELF-DIAGNOSTIC RESULTS
Check the self-diagnostic results.
Is the above displayed in the self-diagnosis display item?
YES >> GO TO 2.
NO >> INSPECTION END
2.CHECK CONNECTOR
1. Disconnect stop lamp switch connector and ABS actuator and electric unit (control unit) connector E56 and check terminals for deformation, disconnection, looseness, and so on. If any malfunction is found, repair or replace terminal.
2. Securely reconnect connectors.
3. Perform self-diagnosis again.
OK or NG
OK >> Connector terminal contact is loose, damaged, open or shorted.
NG >> GO TO 3.
3.CHECK STOP LAMP SWITCH
1. Turn ignition switch OFF and disconnect stop lamp switch harness connector.
2. Operate stop lamp switch and check continuity between stop lamp switch harness connector terminals.
OK or NG
OK >> GO TO 4.
NG >> Replace stop lamp switch.
4.CHECK STOP LAMP SWITCH CIRCUIT
1. Turn ignition switch OFF and disconnect stop lamp switch connector E210 and ABS actuator and electric unit (control unit) connector E56.
2. Check continuity between stop lamp switch harness connector and ABS actuator and electric unit (control unit) harness connector.
OK or NG
OK >> Connect connectors and perform an ABS actuator and electric unit (control unit) self-diagnosis.
NG >> Open or short in harness between stop lamp switch and ABS actuator and electric unit (control unit). Repair or replace applied harness.