Operation CHARM: Car repair manuals for everyone.

Special Repair Requirement





INSPECTION AND ADJUSTMENT


EXHAUST VALVE TIMING CONTROL LEARNING : Special Repair Requirement

1.START
With CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Set selector lever to N position and confirm that following electrical or mechanical loads are not applied.
- Headlamp switch is OFF
- Air conditioner switch is OFF
- Rear defogger switch is OFF
- Steering wheel is in the straight-ahead position, etc.
3. Select "EXH V/T CONTROL LEARN" in "WORK SUPPORT" mode with CONSULT-III.
4. Touch "START" and wait 20 seconds.
5. Keep the engine speed between 2,200 and 4,000 rpm.
6. Check that "CMPLT" is displayed on CONSULT-III screen.

Learning completed : CMPLT
Learning not yet : YET

Without CONSULT-III
1. Disconnect the negative battery terminal and wait at least 10 minutes.
2. Reconnect the negative battery terminal.
3. Start engine and warm it up to normal operating temperature.
4. Set selector lever to N position and confirm that following electrical or mechanical loads are not applied.
- Headlamp switch is OFF
- Air conditioner switch is OFF
- Rear defogger switch is OFF
- Steering wheel is in the straight-ahead position, etc.
5. Keep the engine speed between 2,200 and 4,000 rpm at 20 seconds.
- END