CAN
E-SUS BRANCH LINE CIRCUIT
Diagnosis Procedure
1. CHECK CONNECTOR
1.Turn the ignition switch OFF.
2.Disconnect the battery cable from the negative terminal.
3.Check the terminals and connectors of the E-SUS control unit for damage, bend and loose connection (unit side and connector side).
Is the inspection result normal?
YES- GO TO 2.
NO- Repair the terminal and connector.
2. CHECK HARNESS FOR OPEN CIRCUIT
1.Disconnect the connector of E-SUS control unit.
2.Check the resistance between the E-SUS control unit harness connector terminals.
Is the measurement value within the specification?
YES- GO TO 3.
NO- Repair the E-SUS control unit branch line.
3. CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the E-SUS control unit. C1D18.
Is the inspection result normal?
YES (Present error)-Replace the E-SUS control unit. Exploded View.
YES (Past error)-Error was detected in the E-SUS control unit branch line.
NO- Repair the power supply and the ground circuit.