DTC 2
DTC 2: ACTUATOR COIL OVER CURRENTCircuit Description
The A, B, C, and D are the actuator motor coil terminals. DC 12 V driving voltage is applied between terminals A and C and terminals B and D so that the shock absorber oil valves are rotated at every 7.5° step feed.
Diagnostic Aids
- Inspect the wiring for poor electrical connections between the control unit 24-way connector and the actuator connectors. Look for possible bent, backed out, deformed, or damaged terminals. Check for weak terminal tension as well.
Also check for a chafed wire that could short to bare metal or other wiring. Inspect for a broken wire inside the insulation.
- When diagnosing for a possible intermittent short or open condition, move the wiring harness while observing test equipment for a change.
DTC 2 ACTUATOR COIL OVER CURRENT
Step 1 - 3
Step 4 - 12
Step 13 - 16