Knock Control Self Test Pulse Fault Drive Cycle A
DTC P0606
- Knock control self test pulse fault Drive cycle A:Signal out of range - below minimum.
Possible causes:
- ECM fault.
ECM fault.
CHECK THE FOLLOWING:
- Check if vehicle has had problems with discharged battery or cutting out. This would indicate a problem with the ECM harness or 12V battery supply.
- If these problems are not present check ECM by substitution with a known good unit.
POSSIBLE FAULTS
- Faulty ECM.