P0748
DTC P0748-850 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)DTC P0778-851 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)
DESCRIPTION
DTC Detection Condition:
The hybrid vehicle control ECU turns the SL1, SL2, and SP solenoids on and off to change the gear between low and high.
Wiring Diagram:
Step 1-2:
Step 3-4:
Step 5-6:
Step 6(Continued):
INSPECTION PROCEDURE
CAUTION:
- Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting, check the voltage at the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
HINT: Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.