P0A4D
DTC P0A4B-253 Generator Position Sensor CircuitDTC P0A4C-513 Generator Position Sensor Circuit Range / Performance
DTC P0A4D-255 Generator Position Sensor Circuit Low
DESCRIPTION
DTC Detection Condition:
A resolver is a sensor that detects the position of the magnetic poles, which are indispensable for ensuring highly efficient control of MG2 and MG1.
The generator resolver structure and method of connection with the inverter with converter assembly are the same as those of the motor resolver.
The inverter with converter assembly monitors output signals from the generator resolver and detects malfunctions.
MONITOR DESCRIPTION
Monitor Strategy:
Typical Enabling Conditions:
Typical Malfunction Thresholds:
Component Operating Range:
The MG ECU monitors the generator resolver output signal. If the MG ECU detects output signals that are out of the normal range or specification, it will conclude that there is a malfunction of the generator resolver. The hybrid vehicle control ECU will illuminate the MIL and set a DTC.
Wiring Diagram:
Step 1-2:
Step 2(Continued)-3:
Step 4-5:
Step 5(Continued):
INSPECTION PROCEDURE
CAUTION:
- Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting, check the voltage at the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
NOTE: Check for output DTCs again after the repair has been completed. If P0A78-286 or P0A7A-324 is output, replace the inverter with converter assembly.
HINT:
- Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
- If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.
- If INF code 253 is output, there may be an interphase short in the generator resolver circuit due to an intrusion of water into the resolver. Therefore, if the problem symptom cannot be reproduced, replace the hybrid vehicle transmission assembly last.