P0A93
DTC P0A93-346 Inverter Cooling System PerformanceDESCRIPTION
DTC Detection Condition:
The inverter converts the boosted high-voltage direct-current from the HV battery into alternating current for MG2 and MG1. The inverter generates heat during the conversion process, and this heat could damage the inverter if a cooling system is unavailable. Therefore, similar to MG2 and MG1, the inverter is cooled by a special cooling system consisting of an electric water pump, cooling fan, and radiator. This cooling system is independent of the engine cooling system. The hybrid vehicle control ECU monitors the electric water pump, cooling fan, and cooling system, and detects malfunctions.
MONITOR DESCRIPTION
Monitor Strategy:
Typical Enabling Conditions:
Typical Malfunction Thresholds:
Component Operating Range:
If the hybrid vehicle control ECU detects a malfunction of the electric water pump, fan or radiator, the ECU will illuminate the MIL and set a DTC.
Step 1-2:
Step 2(Continued)-4:
Step 5-7:
Step 7(Continued)-8:
Step 9-11:
Step 11(Continued)-12:
Step 13-14:
Step 14(Continued)-15:
Step 16-18:
Step 18(Continued):
INSPECTION PROCEDURE
CAUTION:
- Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting, check the voltage at the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
NOTE: If the water pump with motor bracket assembly is the final part to be replaced after performing the inspection procedure, be sure to inspect the INV W/P fuse for continuity. If there is no continuity, replace the water pump with motor bracket assembly and the INV W/P fuse.
HINT: Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.