DESCRIPTION

The resistance of the thermistor built into the generator temperature sensor changes in accordance with changes in MG1 temperature. The lower the MG1 temperature, the higher the thermistor resistance. Conversely, the higher the temperature, the lower the resistance.






INSPECTION PROCEDURE

PROCEDURE

1. REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY
(a) Replace the hybrid vehicle transmission assembly Components.
HINT: The generator temperature sensor is not available separately. If it requires replacement, replace the hybrid vehicle transmission assembly.

NEXT -- COMPLETED