P060A
1UR-FSE ENGINE CONTROL SYSTEM: SFI SYSTEM: P060A: Internal Control Module Monitoring Processor Performance
DTC P060A - Internal Control Module Monitoring Processor Performance
MONITOR DESCRIPTION
The main CPU and sub CPU of the ECM perform data communication between each other. The main CPU monitors the communications and WDC pulses from the sub CPU. When the signal malfunctions below are detected, the DTC is output.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
TYPICAL MALFUNCTION THRESHOLDS
INSPECTION PROCEDURE
PROCEDURE
1. READ OUTPUT DTC (DTC P060A)
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream ON.
(d) Clear DTC DTC Check / Clear.
(e) Turn the engine switch off and turn the Techstream OFF.
(f) Disconnect the Techstream.
(g) Disconnect the cable from the negative (-) battery terminal and wait for 1 minute.
(h) Connect the cable to the negative (-) battery terminal.
(i) Connect the Techstream to the DLC3.
(j) Turn the engine switch on (IG).
(k) Turn the Techstream ON.
(l) Select the following menu items: Powertrain / Engine / Trouble Codes.
(m) Read DTCs.
Result:
B -- REPLACE ECM
A -- CHECK FOR INTERMITTENT PROBLEMS