B1780
SUPPLEMENTAL RESTRAINT SYSTEMS: OCCUPANT CLASSIFICATION SYSTEM: B1780: Front Occupant Classification Sensor LH Circuit Malfunction
B1780 - Front Occupant Classification Sensor LH Circuit Malfunction
DESCRIPTION
The front occupant classification sensor LH circuit consists of the occupant classification ECU and front occupant classification sensor LH.
DTC B1780 is stored when a malfunction is detected in the front occupant classification sensor LH circuit.
HINT
When DTC B1650/32 is detected as a result of troubleshooting for the airbag system, check the DTCs stored in the occupant classification ECU. When DTC B1780 is output, perform troubleshooting for the DTC.
WIRING DIAGRAM
INSPECTION PROCEDURE
HINT
* If troubleshooting (wire harness inspection) is difficult to perform, remove the front passenger seat installation bolts to see under the seat cushion.
* In the above case, hold the seat so that it does not fall down. Hold the seat only as necessary because holding the seat for a long period of time may cause seat rail deformation.
PROCEDURE
1. CHECK CONNECTORS
(a) Turn the power switch off.
(b) Disconnect the cable from the negative (-) battery terminal.
(c) Check that the connectors are properly connected to the occupant classification ECU and front occupant classification sensor LH.
OK:
The connectors are properly connected.
HINT
If the connectors are not connected securely, reconnect the connectors and proceed to the next inspection.
(d) Disconnect the connectors from the occupant classification ECU and front occupant classification sensor LH.
(e) Check that the terminals of the connectors are not damaged.
OK:
The terminals are not deformed or damaged.
NG -- REPLACE FRONT SEAT WIRE RH
OK -- Continue to next step.
2. CHECK FRONT SEAT WIRE RH (SHORT TO B+)
(a) Connect the cable to the negative (-) battery terminal.
(b) Turn the power switch on (IG).
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Text in Illustration
NG -- REPLACE FRONT SEAT WIRE RH
OK -- Continue to next step.
3. CHECK FRONT SEAT WIRE RH (OPEN)
(a) Turn the power switch off.
(b) Disconnect the cable from the negative (-) battery terminal.
(c) Using SST, connect terminals 1 (SVC1) and 3 (SGD1), and connect terminals 2 (SIG1) and 3 (SGD1) of connector C.
NOTICE:
Do not forcibly insert SST into the terminals of the connector when connecting.
SST : 09843-18040
(d) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPLACE FRONT SEAT WIRE RH
OK -- Continue to next step.
4. CHECK FRONT SEAT WIRE RH (SHORT)
(a) Disconnect SST from connector C.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPLACE FRONT SEAT WIRE RH
OK -- Continue to next step.
5. CHECK FRONT SEAT WIRE RH (SHORT TO GROUND)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPLACE FRONT SEAT WIRE RH
OK -- Continue to next step.
6. CHECK DTC
(a) Connect the connectors to the occupant classification ECU and front occupant classification sensor LH.
(b) Connect the cable to the negative (-) battery terminal.
(c) Turn the power switch on (IG).
(d) Clear the DTCs stored in the occupant classification ECU Reading and Clearing Diagnostic Trouble Codes.
(e) Clear the DTCs stored in the center airbag sensor assembly DTC Check / Clear.
(f) Turn the power switch off.
(g) Turn the power switch on (IG).
(h) Check for DTCs of the occupant classification ECU Reading and Clearing Diagnostic Trouble Codes.
OK:
DTC B1780 is not output.
HINT
Codes other than DTC B1780 may be output at this time, but they are not related to this check.
NG -- REPLACE FRONT SEAT ASSEMBLY RH
OK -- USE SIMULATION METHOD TO CHECK How To Proceed With Troubleshooting
7. REPLACE FRONT SEAT ASSEMBLY RH
(a) Turn the power switch off.
(b) Disconnect the cable from the negative (-) battery terminal.
(c) Replace the front seat assembly RH Removal.
NEXT -- Continue to next step.
8. PERFORM ZERO POINT CALIBRATION
(a) Connect the cable to the negative (-) battery terminal.
(b) Connect the Techstream to the DLC3.
(c) Turn the power switch on (IG).
(d) Using the Techstream, perform Zero Point Calibration Programming and Relearning.
OK:
"Zero Point Calibration is complete." is displayed.
NEXT -- Continue to next step.
9. PERFORM SENSITIVITY CHECK
(a) Using the Techstream, perform Sensitivity Check Programming and Relearning.
Standard:
27 to 33 kg (59.5 to 72.8 lb)
NEXT -- END