P0A94-442 - DC / DC Converter Performance
HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM: P0A94-442: DC / DC Converter Performance
P0A94-442 - DC / DC Converter Performance
DESCRIPTION
The boost converter boosts the 244.8 V DC from the HV battery to a maximum of approximately 650 V DC. The inverter converts the voltage that has been boosted by the boost converter into alternating current, which is used for driving MG1 and MG2. When a motor generator operates as a generator, the alternating current that it creates is converted into direct current by the inverter. Then the boost converter drops this voltage to direct-current of approximately 244.8 V in order to charge the HV battery.
The MG ECU uses a voltage sensor (VL) that is built into the boost converter to detect the high voltage before it is boosted. It also uses a voltage sensor (VH) that is built into the inverter to detect the high voltage after it is boosted. Based on the voltage before and after it is boosted, the MG ECU controls the operation of the boost converter to boost the voltage to the target voltage.
MONITOR DESCRIPTION
If the difference between the requested boost converter voltage and the actual boost converter voltage exceeds a predetermined value, the MG ECU determines that there is a malfunction of the execution or monitoring in the boost converter voltage. The MG ECU will send information about the malfunction to the hybrid vehicle control ECU. Upon receiving this information, the hybrid vehicle control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
TYPICAL MALFUNCTION THRESHOLDS
COMPONENT OPERATING RANGE
INSPECTION PROCEDURE
CAUTION:
- Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
HINT
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
PROCEDURE
1. CHECK DTC OUTPUT (HV)
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check if DTCs are output.
Result:
HINT
- *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
- P0A94-442 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
(e) Turn the power switch off.
B -- GO TO DTC CHART Hybrid Control System
A -- Continue to next step.
2. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) P0343
NG -- CONNECT SECURELY
OK -- REPLACE INVERTER WITH CONVERTER ASSEMBLY Components