Initialization
SLIDING ROOF: SLIDING ROOF SYSTEM: INITIALIZATION
1. INITIALIZE SLIDING ROOF DRIVE GEAR SUB-ASSEMBLY
NOTICE:
* When the sliding roof glass is replaced or removed and installed, or the drive gear sub-assembly is replaced, the sliding roof drive gear sub-assembly requires initialization (pulse sensor initial position setting), as the glass position cannot be determined. If initialization is not performed, the auto slide open and close / tilt up and down function may not operate, or the sliding roof may move in reverse or become misaligned.
* During initialization, do not apply a physical shock, such as opening/closing a door or driving the vehicle at 5 km/h (3 mph) or more, to the vehicle and do not perform the following electrical operations:
* Cranking the engine
* Turning the power switch from ON (IG) to OFF
* Operating the power window switches
* Operating the window defogger switch
* Operating the blower switch
* Locking/Unlocking the door
* Operating the headlight dimmer switch
HINT
When the cable is disconnected and reconnected to the negative (-) battery terminal or the sliding roof drive gear sub-assembly connector is disconnected and reconnected, the sliding roof drive gear sub-assembly (pulse sensor initial position setting) initialization is not necessary.
(a) Perform initialization according to the table below.
(1) Procedure A
1 Turn the power switch ON (IG).
2 Close the sliding roof to the fully closed position.
3 Press and hold the tilt up switch to perform the following operations: tilt up -> approximately 1 second pause -> tilt down -> slide open -> slide close.
NOTICE:
Make sure not to release the switch during the initialization. If the switch is released, perform the initialization again.
4 The initialization is completed.
(2) Procedure B
1 Turn the power switch ON (IG).
2 Press the tilt up switch until the sliding roof stops.
HINT
If the glass becomes misaligned or does not fully tilt up, perform the following operations:
* Operate the slide close switch until the sliding roof stops moving.
* Operate the tilt up switch until the sliding roof stops moving, then proceed to the next step.
3 Release the switch.
4 Press the tilt up switch for 10 seconds or more to perform the following operations: tilt up -> approximately 1 second pause -> tilt down -> slide open -> slide close.
NOTICE:
Make sure not to release the switch during the initialization. If the switch is released, perform the initialization again.
5 The initialization is completed.
(3) Procedure C
1 Turn the power switch ON (IG).
2 Press and hold the slide close switch to perform the following operations: slide close -> move in reverse direction -> 10 second pause -> slide close.
NOTICE:
Make sure not to release the switch during the initialization. If the switch is released, perform the initialization again.
3 After the sliding roof stops in the fully closed position, release the switch.
4 Perform procedure A.