Operation CHARM: Car repair manuals for everyone.

P043E





2AZ-FXE ENGINE CONTROL: SFI SYSTEM: P043E, P043F, P2401, P2402, P2419: Evaporative Emission System Reference Orifice Clog Up

DTC SUMMARY





HINT
The reference orifice is located inside the canister pump module.

DESCRIPTION

The description can be found in the EVAP (Evaporative Emission) System EVAP System.

MONITOR DESCRIPTION

5 hours*1 after the power switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The hybrid vehicle control ECU monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT
*1: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the power switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the power switch is turned off, the monitor check starts 2.5 hours later.





*2: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.









The leak detection pump creates negative pressure through the reference orifice. When the system is normal, the EVAP pressure is in 97 to 100 kPa(abs) (728 to 750 mmHg(abs))* and saturated within a minute.

If not, the hybrid vehicle control ECU interprets this as a malfunction. The hybrid vehicle control ECU will illuminate the MIL and set DTC if this malfunction is detected in consecutive driving cycle.

*: Typical valve

MONITOR STRATEGY





TYPICAL ENABLING CONDITIONS





TYPICAL MALFUNCTION THRESHOLDS

"Saturated" indicates that the EVAP pressure change is below 0.286 kPa(gauge) [2.145 mmHg(gauge)] in 60 seconds.





MONITOR RESULT

Refer to Checking Monitor Status Mode 6 Data.

CONFIRMATION DRIVING PATTERN

NOTICE:
- The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the Techstream. It takes a maximum of approximately 24 minutes.
- Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
- Do not run the engine during this operation.
- When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F).

1. Connect the Techstream to the DLC3.

2. Turn the power switch on (IG) and turn the Techstream on.

3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure) Reading and Clearing Diagnostic Trouble Codes.

4. Turn the power switch off and wait for 30 seconds.

5. Turn the power switch on (IG) and turn the Techstream on.

6. Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

7. After the "Evaporative System Check" is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All readiness.

8. Input the DTC: P043E, P043F, P2401, P2402 or P2419.

9. Check the DTC judgment result.





HINT
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.

10. If the judgment result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs Reading and Clearing Diagnostic Trouble Codes.

HINT
- If a permanent DTC is output, the system is malfunctioning.
- If no permanent DTC is output, the system is normal.

INSPECTION PROCEDURE

Refer to the EVAP System EVAP System.