XB124 - Check HFP Circuit For Short to Ground
- Key "OFF".
- Variable Control Relay Module (VCRM) disconnected.
- High Speed Fuel Pump (HFP) relay disconnected.
- Measure resistance between Pin 10 at the VCRM vehicle harness connector and the battery negative post.
- Is resistance greater than 10,000 ohms?
Yes -- Replace HFP relay. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)
No -- Service HFP circuit short to ground. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)