XB167 - Check HFP Circuit For Short to Ground
- Key "OFF".
- High Speed Fuel Pump (HFP) relay disconnected.
- Variable Control Relay Module (VCRM) disconnected.
- Measure resistance between the HFP circuit at the HFP relay vehicle harness connector and the battery negative post.
- Is resistance greater than 10,000 ohms?
Yes -- Replace VCRM. Reconnect all components. Re-evaluate symptom.
No -- Service HFP circuit short to ground. Reconnect all components. Re-evaluate symptom.