B Code Charts
DTC B1873: Turn Signal/Hazard Power Feed Short To GroundB1873-1 - Rerun Test
- Verify that all switches are off and ignition switch is in RUN.
- Clear DTC.
- Perform On-Demand self test.
Is DTC B1873 still present?
YES GO to B1873-3.
NO GO to B1873-2
B1873-2 - Check Switch
- Read PID FLSHPWR.
- Turn ignition switch to RUN.
- Toggle hazard switch several times.
Does PID show that flasher power is present at all times, except momentarily while switch is between states?
YES System operating normally.
NO REPLACE multi-function switch. RETEST system.
B1873-3 - Check Switch PID
- Read PID FLSHPWR.
- Turn ignition switch to RUN.
Does PID show that power is on?
YES REPLACE lighting control module. RETEST system.
NO GO to B1873-4.
B1873-4 - Check Circuit 385 (W/R)
- Turn hazard switch ON.
- Read PID FLSHPWR.
Does PID show that power is on?
YES SERVICE Circuit 298 (P/O) to multi-function switch. RETEST system.
NO SERVICE Circuit 385 (W/R) from multi-function switch to lighting control module. RETEST system.