Test F: The Charging System Warning Indicator Flickers or Is Intermittent
PINPOINT TEST F: THE CHARGING SYSTEM WARNING INDICATOR FLICKERS OR IS INTERMITTENTF1-F3:
F4:
Normal Operation
With the engine running, the charging system warning indicator should be off. The sense A-circuit 30-BA25 (RD) to the generator field coil carries 13-15 volts. The I-circuit 10-BA25 (GY/RD) is used to turn on the voltage regulator. This circuit carries 0 volts (C102a connected) with the key ON and the engine not running (1-8 volts with the engine running). The positive battery output (B+) circuit 30-BA6 (RD) is the generator output supplied to the battery and the electrical system.
If the I-circuit 10-BA25 (GY/RD) is open or shorted to ground, the generator does not function. If the engine speed exceeds 3,000 rpm, the generator self-excites, and begins to function normally (the battery light turns off and the generator operates normally) until the engine is turned off. This is a limp-home mode for customer safety.
Possible Causes
- rear battery junction box (BJB) fuse 15 (5A) connections
- generator
- generator connections
- instrument cluster