Test J: The Doors Do Not Lock/Unlock Using The Remote Keyless Entry Keypad
PINPOINT TEST J: THE DOORS DO NOT LOCK/UNLOCK USING THE REMOTE KEYLESS ENTRY KEYPADJ1-J4:
J4-J5:
J6-J8:
J8-J10:
Normal Operation
When the customer code buttons are pressed on the remote keyless entry (RKE) keypad, a signal is sent on circuits 7-AA70 (YE/GN), 8-AA70 (WH/GN), and 10-AA70 (GY/OG) by completing the selected circuit buttons to circuit 9-AA70 (BN/GN), to the driver door module (DDM) to activate the function requested. The customer code is entered to unlock the driver door. Entering the customer code and pressing the 3/4 button unlocks all the doors. Pressing 7/8 and 9/0 locks all the doors. No customer code is required to lock the doors using the RKE keypad.
If memory settings are programmed, customer code 1 is used to unlock the door and recall memory position 1. Customer Code 2 is used to unlock the door and recall memory position 2.
Possible Causes
- circuit 7-AA70 (YE/GN) short to ground or open
- circuit 8-AA70 (WH/GN) short to ground or open
- circuit 9-AA70 (BN/GN) open
- circuit 10-AA70 (GY/OG) short to ground or open
- RKE keypad
- DDM