Pinpoint Test D: DTC B2574, B2575 Or B2A25




Locks, Latches and Entry Systems - Integrated Keyhead Transmitter (IKT)







Pinpoint Tests

Pinpoint Test D: DTC B2574, B2575 Or B2A25

Refer to Wiring Diagram Set 117, Remote Keyless Entry and Alarm for schematic and connector information. Diagrams By Number

Normal Operation

The Smart Junction Box (SJB) sends voltage signals to the passenger door lock control switch through circuits CPK19 (BU/GN) and CPK23 (YE/VT) for the lock and unlock requests. When the lock or unlock switch is pressed, the voltage signal is routed to ground.

The Driver Door Module (DDM) sends voltage signals to the driver door lock control switch through circuits CPK19 (BU/GN) and CPK23 (YE/VT) for the lock and unlock requests. When the lock or unlock switch is pressed, the voltage signal is routed to ground.

The driver door lock control switch is grounded through circuit GD133 (BK) and the passenger switch is grounded through circuit GD145 (BK/BU).

Both modules share the information obtained from the door lock switch inputs over the Medium Speed Controller Area Network (MS-CAN).

- DTC B2574 (Drivers Door LOCK Switch Short to Ground) - a continuous and on-demand DTC that sets when the DDM detects a short to ground on circuit CPK19 (BU/GN). This code will also set if the driver door lock control switch is pressed for longer than 2 minutes.
- DTC B2575 (Drivers Door UNLOCK Switch Short to Ground) - a continuous and on-demand DTC that sets when the DDM detects a short to ground on circuit CPK23 (YE/VT). This code will also set if the driver door lock control switch is pressed for longer than 2 minutes.
- DTC B2A25 (Trim Panel Lock Switch Circuit Failure) - an on-demand DTC for the passenger door lock control switch that sets if the SJB detects a short to ground on circuit CPK19 (BU/GN) or CPK23 (YE/VT). This DTC may also set if the passenger door lock control switch is pressed for longer than 2 minutes.

This pinpoint test is intended to diagnose the following:

- Wiring, terminals or connectors
- Door lock control switch
- DDM
- SJB



PINPOINT TEST D: DTC B2574, B2575 OR B2A25

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.

-------------------------------------------------
D1 CHECK THE RECORDED SJB DTCs FROM THE SELF-TEST


- Check the recorded results from the SJB self-test.
- Is DTC B2A25 present?

Yes
GO to D2.

No
For DTCs B2574 and B2575, GO to D4.

-------------------------------------------------
D2 CHECK THE RH DOOR LOCK CONTROL SWITCH


- Disconnect: RH Door Lock Control Switch C605.
- Repeat the SJB self-test.
- Is DTC B2A25 retrieved again?

Yes
GO to D3.

No
INSTALL a new RH door lock control switch. REFER to Door Lock Control Switch Service and Repair. TEST the system for normal operation.

-------------------------------------------------
D3 CHECK THE SJB LOCK OR UNLOCK INPUT CIRCUIT FOR A SHORT TO GROUND


- Ignition OFF.
- Disconnect: SJB C2280c.
- Measure the resistance between the RH door lock control switch C605-4, circuit CPK19 (BU/GN), harness side and ground; and between the RH door lock control switch C605-2, circuit CPK23 (YE/VT), harness side and ground.




- Are the resistances greater than 10,000 ohms?

Yes
GO to D7.

No
REPAIR the circuit in question. CLEAR the DTCs. REPEAT the self-test.

-------------------------------------------------
D4 CHECK THE LH DOOR LOCK CONTROL SWITCH


- Disconnect: LH Door Lock Control Switch C541.
- Repeat the DDM self-test.
- Is DTC B2574 or B2575 retrieved again?

Yes
LEAVE the switch disconnected. GO to D5.

No
INSTALL a new LH door lock control switch. REFER to Door Lock Control Switch Service and Repair. TEST the system for normal operation.

-------------------------------------------------
D5 CHECK THE DDM LOCK OR UNLOCK INPUT CIRCUIT FOR A SHORT TO GROUND


- Ignition OFF.
- Disconnect: DDM C501b.
- Measure the resistance between the LH door lock control switch C541-4, circuit CPK19 (BU/GN), harness side and ground; and between the LH door lock control switch C541-2, circuit CPK23 (YE/VT), harness side and ground.




- Are the resistances greater than 10,000 ohms?

Yes
GO to D6.

No
REPAIR the circuit in question. CLEAR the DTCs. REPEAT the self-test.

-------------------------------------------------
D6 CHECK FOR CORRECT DDM OPERATION


- Disconnect all the DDM connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the DDM connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?

Yes
INSTALL a new DDM. TEST the system for normal operation.

No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.

-------------------------------------------------
D7 CHECK FOR CORRECT SJB OPERATION


- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?

Yes
INSTALL a new SJB. TEST the system for normal operation.

No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.

-------------------------------------------------