Flow Chart No. 1: One Door Lock Inoperative
Flow Chart No.1 - Symptom - One door lock inoperative.Step 1
Check operation of suspect door lock.
1. Manually operate inoperative door lock, checking for binding or stuck condition.
2. Is lock stuck or binding?
Step 2
Check suspect power door lock actuator lock operation.
1. Gain access to, then disconnect, suspect power door lock actuator.
NOTE
^ Reconnect door lock switch connector.
2. Check voltage at P/B wire of door lock actuator connector while pressing "Lock" on door lock switch.
3. Is battery voltage present?
Step 3
Check power door lock actuator for unlock operation.
1. Connect voltmeter to R/O wire at door lock actuator connector.
2. Actuate switch in the unlock position.
3. Is battery voltage present?
Step 4
Check power door lock actuator.
1. Using two 10-gauge jumper wires connected to battery positive (+) and battery negative (-), attach jumpers to actuator connector; reverse polarity for opposite direction.
2. Did actuator operate correctly?
Step 5
Check power door lock actuator.
1. Using ammeter, check current draw of actuator.
2. Is current draw 6 amps or less?