Pinpoint Test 3
PINPOINT TEST 3: DTC B1555 - IGNITION RUN CIRCUIT FAILURE OR NO POWER IN RUN
Step 1-Step 3:
Step 4:
Normal Operation
The ignition switch RUN circuit provides fused battery voltage along circuits (W/O), (BR/Y) and (V/G) to the smart junction box (SJB) when the key is in the RUN position.
Possible Causes
- Fuse
- Circuit open
- Ignition switch
- SJB
CAUTION: Use the Flex Probe Kit for all test connections to prevent damage to the wiring terminals. Do not use standard multimeter probes.