Pinpoint Test 4
PINPOINT TEST 4: NO POWER IN STARTStep 1-Step 3:
Normal Operation
The ignition switch START circuit provides fused battery voltage along circuits (L/W) and (W/O) to the smart junction box (SJB) when the key is in the START position.
Possible Causes
- Fuse
- Circuit open
- Circuit shorted
- Ignition switch
- SJB
CAUTION: Use the Flex Probe Kit for all test connections to prevent damage to the wiring terminals. Do not use standard multimeter probes.