Pinpoint Test 13: The RH Turn Signal Indicator Is Never On
PINPOINT TEST 13: THE RH TURN SIGNAL INDICATOR IS NEVER ON
Normal Operation
When the multifunction switch is in the RH TURN position, voltage is sent from the multifunction switch to the instrument cluster through circuit (GY/Y), and the RH turn signal indicator flashes on and off. The instrument cluster provides the bulb ground through circuit (B/Y).
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Instrument cluster
CAUTION:Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.