[AW6A-EL]
TCM INSPECTION [AW6A-EL]TR Switch Operating Inspection
1. Verify that the starter operates only when the ignition switch is turned to the START position with the selector lever in P or N position.
^ If there is any malfunction, neutral position learning.
2. Verify that the back-up lights illuminate when shifted to R position with the ignition switch at the ON position.
^ If there is any malfunction, neutral position learning.
3. Verify that the positions of the selector lever and the indicator light correspond.
^ If there is any malfunction, perform the neutral position learning.
4. Verify that the TR PID is normal.
^ If there is any malfunction, perform the neutral position learning.
Control Module Inspection
1. Remove the air cleaner component.
2. Measure the voltage at each TCM short cord connector wiring harness-side) terminal and refer to the terminal voltage table.
^ If the voltage is not as specified in the Terminal Voltage Table (Reference), inspect the parts under "Inspection item (s)".
Warning
^ Be careful not to damage the connector waterproofing when measuring the TCM terminal voltage. If damaged, the waterproofing efficiency could be negatively affected.
Note
^ Use the ground of terminal J of the TCM short cord connector wiring harness-side) when measuring terminal voltage, as an error may occur when connecting the negative circuit tester to ground.
Terminal Voltage Table (Reference)
Terminal Voltage (Reference):
3. Remove the TCM.
4. Verify that continuity or resistance at terminal is as indicated in the terminal continuity/resistance table.
^ If there is any malfunction, inspect the parts under "Inspection item (s)".
^ If the system does not work properly even though the parts or related wiring harnesses do not have any malfunction, replace the TCM.
Terminal Continuity/Resistance Table (Reference)