Variable Tumble Solenoid Valve Inspection
VARIABLE TUMBLE SOLENOID VALVE INSPECTION [LF, L3]
1. Remove the variable tumble solenoid valve. Service and Repair
2. Inspect airflow between the ports under the following conditions.
- If not as specified, replace the variable tumble solenoid valve.
- If as specified, carry out the "Circuit Open/Short Inspection".
LF
L3
Circuit Open/Short Inspection
1. Disconnect the PCM connector. Service and Repair
2. Inspect the following wiring harness for open or short (continuity check).
Open circuit
- If there is no continuity, the circuit is open. Repair or replace the wiring harness.
- Variable tumble solenoid valve terminal B and PCM terminal 2I*1, 2AI*2
- Variable tumble solenoid valve terminal A and main relay terminal A
Short circuit
- If there is continuity, the circuit is shorted. Repair or replace the wiring harness.
- Variable tumble solenoid valve terminal A and body ground
- Variable tumble solenoid valve terminal B and power supply
*1
California emission regulation applicable model and except for California emission regulation applicable model with LF MTX, L3
*2
Except for California emission regulation applicable model with LF ATX