Variable Tumble Shutter Valve Actuator Inspection
VARIABLE TUMBLE SHUTTER VALVE ACTUATOR INSPECTION [L5]
1. Remove the air hose. Service and Repair
2. Disconnect the vacuum hose from the variable tumble shutter valve actuator.
3. Connect a vacuum pump to the variable tumble shutter valve actuator.
4. Apply vacuum and verify that the rod moves.
- If the rod does not move, replace the intake manifold. Service and Repair