Hazard Warning Switch: Testing and Inspection
HAZARD WARNING SWITCH INSPECTION
1. Disconnect the negative battery cable.
2. Remove the center panel upper. Center Panel Upper Removal/Installation
3. Remove the hazard warning switch. Service and Repair
4. Verify that the continuity between the hazard switch terminals is as indicated in the table.
- If not as indicated in the table, replace the hazard warning switch.
5. Apply battery voltage to hazard switch terminal D, and connect terminal C to ground.
6. Verify that the LED illuminates.
- If there is any malfunction, replace the hazard warning switch.