Metering Oil Pump Driver Removal/Installation
METERING OIL PUMP DRIVER REMOVAL/INSTALLATION [13B-MSP]
1. Remove the battery cover. Removal and Replacement
2. Disconnect the negative battery cable.
3. Disconnect the metering oil pump driver connector.
4. Remove the metering oil pump driver.
5. Install in the reverse order of removal.