Auxiliary Port Valve (APV) Motor Inspection
AUXILIARY PORT VALVE (APV) MOTOR INSPECTION [13B-MSP]
Resistance Inspection
1. Remove the APV motor. Overhaul
2. Measure the resistance between the APV motor terminals.
- If not as specified, replace the APV motor. Overhaul
- APV motor resistance
8-50 ohms [20 °C {68 °F}]
Operation Inspection
CAUTION:
- Applying voltage to the APV motor terminals for more than 3 s may damage the APV motor.
1. Disconnect the negative battery cable.
2. Remove the APV motor. Overhaul
3. Apply 12 V with a current of 0.9-1.9 A to terminal B or D and verify that the gear moves.
- If there is any malfunction, replace the APV motor. Overhaul
- If as specified, carry out the "Circuit Open/Short Inspection".
Circuit Open/Short Inspection
1. Disconnect the PCM connector. Service and Repair
2. Inspect the following wiring harnesses for open or short (continuity check).
Open circuit
- If there is no continuity, the circuit is open. Repair or replace the wiring harness.
- APV motor terminal B and PCM terminal 2F
- APV motor terminal D and PCM terminal 2D
Short circuit
- If there is no continuity, the circuit is shorted. Repair or replace the wiring harness.
- APV motor terminal B and power supply
- APV motor terminal B and body GND
- APV motor terminal D and power supply
- APV motor terminal D and body GND