Variable Induction Position Sensor: Testing and Inspection
VARIABLE TUMBLE SHUTTER VALVE SWITCH INSPECTION [L3]
1. Connect the M-MDS to the DLC-2.
2. Turn the ignition switch to the ON position.
3. Verify that the voltage (M-MDS PID: VTC) within the specification. Component Tests and General Diagnostics
- If not as specified, replace the intake manifold. Service and Repair