Operation CHARM: Car repair manuals for everyone.

Tests AD: The Power Liftgate Reverses During The Power Close Operation

PINPOINT TEST AD: THE POWER LIFTGATE REVERSES DURING THE POWER CLOSE OPERATION


AD1-AD4:






AD4-AD5:






AD6-AD8:






AD8-AD9:






AD9-AD11:






AD11-AD13:






Normal Operation
When the power liftgate moves in the close direction, the PLG module monitors the pinch strips and optical sensor for obstacle detection. The PLG module uses a 5-volt reference signal on circuit 1966 (LB/BK) and a return signal on circuit 1967 (GY/OG) for the left pinch strip. The PLG module uses a 5-volt reference signal on circuit 1965 (VT) and a return signal on circuit 1967 (GY/OG) for the right pinch strip. The right and left pinch strip return signal circuits are spliced together.

Possible Causes
- PLG module DTC B2704 Optical Sensor Power Short To Ground
- PLG module DTC B2908 Latch Switch Invalid
- PLG module DTC B2931 Optical Sensor 1 Short To Battery Or Open
- PLG module DTC B2932 Optical Sensor 1 Short To Ground
- PLG module DTC B2933 Optical Sensor 2 Short To Battery Or Open
- PLG module DTC B2934 Optical Sensor 2 Short To Ground
- circuit 1205 (BK) open
- circuit 1962 (LG/VT), 1963 (OG/LB) or 1964 (DG/WH) open or short to ground
- circuit 1968 (YE) or 1969 (WH/YE) open, short to voltage or short to ground
- circuit 1970 (RD/LB) open or short to ground
- circuit 1971 (LB/OG) open
- mechanical binding
- power liftgate latch
- optical sensor
- PLG module