Tests AF: The Power Liftgate Pinch Strip Does Not Stop/Reverse The Liftgate
PINPOINT TEST AF: THE POWER LIFTGATE PINCH STRIP DOES NOT STOP/REVERSE THE LIFTGATEAF1-AF2:
AF2-AF4:
Normal Operation
When the power liftgate moves in the close direction, the PLG module monitors the pinch strips and optical sensor for obstacle detection. The PLG module uses a 5-volt reference signal on circuit 1966 (LB/BK) and a return signal on circuit 1967 (GY/OG) for the left pinch strip. The PLG module uses a 5-volt reference signal on circuit 1965 (VT) and a return signal on circuit 1967 (GY/OG) for the right pinch strip. The right and left pinch strip return signal circuits are spliced together.
Possible Causes
- PLG module DTC B2699 Left Pinch Strip Open Or Short To Battery
- PLG module DTC B2700 Right Pinch Strip Open Or Short To Battery
- circuit 1965 (VT), 1966 (LB/BK) or 1967 (GY/OG) open
- pinch strip
- PLG module