Operation CHARM: Car repair manuals for everyone.

Tests AG: The Power Liftgate Does Not Power Close (Power Open OK)

PINPOINT TEST AG: THE POWER LIFTGATE DOES NOT POWER CLOSE (POWER OPEN OK)


AG1-AG3:






AG3-AG5:






AG5-AG6:






AG6-AG7:






AG8-AG9:






Normal Operation
When the power liftgate moves in the close direction, the PLG module monitors the pinch strips and optical sensor for obstacle detection. The PLG module uses a 5-volt reference signal on circuit 1966 (LB/BK) and a return signal on circuit 1967 (GY/OG) for the left pinch strip. The PLG module uses a 5-volt reference signal on circuit 1965 (VT) and a return signal on circuit 1967 (GY/OG) for the right pinch strip. The right and left pinch strip return signal circuits are spliced together.

NOTE: Initialize the power liftgate before proceeding with this pinpoint test. Refer to Power Liftgate Initialization.

Possible Causes
- PLG module DTC B2701 Left Pinch Strip Stuck Active
- PLG module DTC B2702 Right Pinch Strip Stuck Active
- PLG module DTC B2908 Latch Switch Invalid
- circuit 1205 (BK) open
- circuit 1962 (LG/VT), 1963 (OG/LB) or 1964 (DG/WH) open or short to ground
- circuit 1965 (VT) or 1966 (LB/BK) short to ground
- power liftgate latch
- pinch strip
- PLG module