Test U: The Panel/Floor Control Is Inoperative Using The Front Auxiliary Climate Controls
PINPOINT TEST U: THE PANEL/FLOOR CONTROL IS INOPERATIVE USING THE FRONT AUXILIARY CLIMATE CONTROLSU1:
U1-U3:
U3-U5:
U5-U6:
Normal Operation
Under normal operation, the auxiliary mode door actuator motor is driven to the floor position by supplying voltage to the motor on circuit 1128 (GY/LB) and ground to circuit 1129 (BN/WH).
The auxiliary mode door actuator motor is driven to the panel position by supplying voltage to the motor on circuit 1129 (BN/WH) and ground to circuit 1128 (GY/LB).
Possible Causes
- An open, short to voltage, ground or together in circuits 1128 (GY/LB) or 1129 (BN/WH).
- Front auxiliary climate control assembly.
- Auxiliary mode door actuator motor.
- Broken/binding auxiliary mode door.