Tests AF: The Power Liftgate (PLG) Pinch Strip Does Not Stop/Reverse the Liftgate
PINPOINT TEST AF: THE POWER LIFTGATE (PLG) PINCH STRIP DOES NOT STOP/REVERSE THE LIFTGATEAF1-AF2:
AF2-AF3:
AF3-AF4:
Normal Operation
When the PLG moves in the close direction, the PLG module monitors the pinch strips and optical sensor for obstacle detection. The PLG module uses a 5-volt reference signal on circuit 1966 (LB/BK) and a return signal on circuit 1967 (GY/OG) for the left pinch strip. The PLG module uses a 5-volt reference signal on circuit 1965 (VT) and a return signal on circuit 1967 (GY/OG) for the right pinch strip. The right and left pinch strip return signal circuits are spliced together.
Possible Causes
- PLG module DTC B2699 left pinch strip open or short to battery
- PLG module DTC B2700 right pinch strip open or short to battery
- Circuit 1965 (VT), 1966 (LB/BK) or 1967 (GY/OG) open
- Pinch strip