Tests AG: The Power Liftgate Does Not Power Close (Power Open OK)
PINPOINT TEST AG: THE POWER LIFTGATE DOES NOT POWER CLOSE (POWER OPEN OK)AG1-AG2:
AG3-AG5:
AG5-AG6:
AG7-AG9:
Normal Operation
When the power liftgate (PLG) moves in the close direction, the PLG module monitors the pinch strips and optical sensor for obstacle detection. The PLG module uses a 5-volt reference signal on circuit 1966 (LB/BK) and a return signal on circuit 1967 (GY/OG) for the left pinch strip. The PLG module uses a 5-volt reference signal on circuit 1965 (VT) and a return signal on circuit 1967 (GY/OG) for the right pinch strip. The right and left pinch strip return signal circuits are spliced together.
NOTE: Initialize the PLG before proceeding with this pinpoint test. Refer to Power Liftgate Initialization.
Possible Causes
- PLG module DTC B2701 left pinch strip stuck active
- PLG module DTC B2702 right pinch strip stuck active
- PLG module DTC B2908 latch switch invalid
- Circuit 1205 (BK) open
- Circuit 1962 (LG/VT), 1963 (OG/LB) or 1964 (DG/WH) open or short to ground
- Circuit 1965 (VT) or 1966 (LB/BK) short to ground
- PLG latch
- Pinch strip
- PLG module