Work Flow
DIAGNOSIS AND REPAIR WORK FLOW
Work Flow
DETAILED FLOW
1.CONFIRM SYMPTOM
Confirm symptom or customer complaint.
GO TO 2
2.CHECK SELF-DIAGNOSIS OPERATION OF COMBINATION METER
Perform self-diagnosis of combination meter. Refer to Diagnosis Description.
Does self-diagnosis mode operate?
YES - GO TO 3
NO - Check power supply and ground circuit of combination meter. Refer to Combination Meter BCM (Body Control Module) BCM (Body Control Module). Then, GO TO 4
3.CHECK COMBINATION METER (CONSULT-III)
Select "METER/M&A" on CONSULT-III and perform "SELF-DIAGNOSIS" of combination meter. Refer to CONSULT-III Function.
Self-diagnostic results content
No malfunction detected. Repair or replace the cause of symptom. Then, GO TO 4
Malfunction detected. Refer to Testing and Inspection. Then, GO TO 4
4.CONFIRM OPERATION
Does the combination meter operate normally?
YES or NO
YES - Inspection End.
NO - GO TO 1