Removal and Replacement
GENERATOR
Removal and Installation
REMOVAL
1. Disconnect the negative battery terminal.
2. Remove the fan shroud. Refer to Exploded View.
3. Remove the drive belt. Refer to Removal and Installation.
4. Remove the generator stay, using power tools.
5. Remove the generator upper bolt, using power tools.
6. Disconnect the generator harness connectors.
7. Remove the generator.
GENERATOR PULLEY INSPECTION
Perform the following.
- Make sure that the generator pulley does not rattle.
- Make sure that the generator pulley nut is properly tightened.
Generator pulley nut : 118 N.m (12.0 kg-m, 87 ft-lb)
INSTALLATION
Installation is in the reverse order of removal.
- Install the generator and check tension of drive belt. Refer to Testing and Inspection.
Terminal "1" nut : 10.8 N.m (1.1 kg-m, 8 ft-lb)
CAUTION:
Tighten terminal "1" nut carefully.
- For this model, the power generation variable voltage control system that controls the power generation voltage of the generator has been adopted. Therefore, the power generation variable voltage control system inspection should be performed after replacing the generator in order to ensure that the system operates normally. Refer to Power Generation Voltage Variable Control System Operation Inspection.