Diagnosis Procedure
CLOSE SWITCH
Description
The close switch is integrated in the door lock assembly, and it detects the close condition of the back door lock.
CLOSE SWITCH
Diagnosis Procedure
1.CHECK AUTOMATIC BACK DOOR CONTROL UNIT OUTPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect back door lock assembly connector.
3. Check voltage between back door lock assembly harness connector and ground.
Is the inspection result normal?
YES - GO TO 3.
NO - GO TO 2.
2.CHECK CLOSE SWITCH CIRCUIT
1. Disconnect automatic back door control unit connector.
2. Check continuity between automatic back door control unit harness connector and back door lock assembly harness connector.
3. Check continuity between automatic back door control unit harness connector and ground.
Is the inspection result normal?
YES - Replace automatic back door control unit. Removal And Installation.
NO - Repair or replace harness.
3.CHECK CLOSE SWITCH GROUND CIRCUIT
Check continuity between back door lock assembly harness connector and ground.
Is the inspection result normal?
YES - GO TO 4.
NO - Repair or replace harness.
4.CHECK CLOSE SWITCH
Component Inspection.
Is the inspection result normal?
YES - GO TO 5.
NO - Replace back door lock assembly. Removal And Installation.
5.CHECK INTERMITTENT INCIDENT
Intermittent Incident.
- INSPECTION END