Refrigerant Pressure Sensor / Switch: Service and Repair
REFRIGERANT PRESSURE SENSOR
Removal and Installation for Refrigerant Pressure Sensor
REMOVAL
1. Discharge the refrigerant. HFC-134A (R-134A) Service Procedure.
2. Disconnect the refrigerant pressure sensor harness connector and remove the refrigerant pressure sensor from the condenser.
CAUTION:
Be careful not to damage the condenser fins.
INSTALLATION
Installation is in the reverse order of removal. Component.
CAUTION:
- Be careful not to damage the condenser fins.
- Replace the O-ring of the refrigerant pressure sensor with a new one, then apply compressor oil to it for installation.
- After charging refrigerant, check for leaks.