Operation CHARM: Car repair manuals for everyone.

Removal and Installation





GENERATOR


Removal and Installation


REMOVAL
1. Disconnect the negative battery terminal. Removal And Installation.
2. Partially drain the engine coolant. Service and Repair.
3. Remove engine under cover (front) and air dam (center).
4. Remove air duct and resonator assembly. Exploded View.
5. Remove upper radiator hose.

NOTE:
Cap or plug opening(s) to prevent fluid from spilling.
6. Disconnect coolant reservoir hose from radiator.

NOTE:
Cap or plug opening(s) to prevent fluid from spilling.
7. Remove the fan shroud. Exploded View.
8. Remove engine cooling fan (Motor Driven Type). Removal and Installation (Motor Driven Type).
9. Remove the drive belt. Removal And Installation.
10. Remove the generator stay, using power tools.
11. Remove the generator upper bolt, using power tools.
12. Disconnect the generator harness connectors.
13. Remove the generator.

INSTALLATION
Installation is in the reverse order of removal.
- Install the generator and check tension of drive belt. Procedures.






CAUTION:
Tighten terminal nut carefully.
- For this model, the power generation variable voltage control system that controls the power generation voltage of the generator has been adopted. Therefore, the power generation variable voltage control system inspection should be performed after replacing the generator in order to ensure that the system operates normally. Power Generation Voltage Variable Control System Operation Inspection.