Refrigerant Pressure Sensor / Switch: Service and Repair
REFRIGERANT PRESSURE SENSOR
Removal and Installation
REMOVAL
1.Discharge the refrigerant. HFC-134A (R-134A) Service Procedure.
2.Disconnect the refrigerant pressure sensor harness connector and remove the refrigerant pressure sensor from the condenser.
CAUTION:
Be careful not to damage the condenser fins.
INSTALLATION
Installation is in the reverse order of removal.
Component.
CAUTION:
- Be careful not to damage the condenser fins.
- Do not reuse O-rings.
- Apply A/C oil to the O-ring of the refrigerant pressure sensor for installation.
- After charging refrigerant, check for leaks.