Special Repair Requirement
INSPECTION AND ADJUSTMENT
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special Repair Requirement
INTERRUPTION DETECTION FUNCTION
The CPU of sunroof motor monitors the sunroof motor operation and the sunroof position (fully-closed or other) by the signals from sunroof motor.
When sunroof motor detects an interruption during the following sliding close operation, sunroof switch controls the motor for open and the sunroof will operate until full open position.
- automatic close operation when ignition switch is in the ON position.
- automatic close operation during retained power operation.
INITIALIZATION PROCEDURE
If the sunroof does no close or open automatically, use the following procedure to return sunroof operation to normal.
1.Close the sunroof if it is not in the closed position. It may be necessary to repeatedly push the switch to close the sunroof.
2.Press and hold the TILT UP switch the sunroof will tilt up. Release the button.
3.Press and hold the TILT UP switch again. Do not release the switch, keep pressure on it. After 4 seconds of depressing, the sunroof will full close.
4.Initializing procedure is complete. Confirm proper operation of the sunroof (slide open, slide close, tilt up, tilt down.)
ANTI-PINCH FUNCTION
1.Full open the sunroof.
2.Place a piece of wood near fully closed position.
3.Close the sunroof completely with auto-slide close.
Check that sunroof lowers for approximately 210 mm (8.26 in) with out pinching a piece of wood and stops.
CAUTION:
- Check that auto-slide operates before inspection when system initialization is performed.
- Depending on environment and driving conditions, if a similar impact or lord is applied to the sunroof it may lower.
- Do not check with hands and other part of body because they may be pinched. Do not get pinched.
- Perform initial setting when auto-slide operation or anti-pinch function does not operate normally.