Inhibitor Switch Inspection
INHIBITOR SWITCH1. Check continuity between terminals (1) and (2) and between terminals (3) and (4), (5), (6), (7), (8), (9) while moving selector lever through each range.
2. If NG, check again with manual control linkage disconnected from manual shaft of A/T assembly. Refer to step 1.
3. If OK on step 2, adjust manual control linkage.
Shift Linkage
4. If NG on step 2, remove inhibitor switch from A/T and check continuity of inhibitor switch terminals. Refer to step 1.
5. If OK on step 4, adjust inhibitor switch.
Adjustments
6. If NG on step 4, replace inhibitor switch.