Operation CHARM: Car repair manuals for everyone.

DTC 1005




The EGRC-solenoid valve responds to signals from the ECM. When the ECM sends an ON (ground) signal, the coil in the solenoid valve is energized. A plunger will then move to cut the vacuum signal (from the throttle body to the EGR valve.)
When the ECM sends an OFF signal, the vacuum signal passes through the solenoid valve. The signal then reaches the EGR valve.




OVERALL FUNCTION CHECK
Use this procedure to check the overall function of the EGRC-solenoid valve circuit. During this check, a 1st trip DTC might not be confirmed.

With Consult
(1) Turn ignition switch "ON".




(2) Perform "EGRC SOL/V CIRCUIT" in "FUNCTION TEST" mode with CONSULT.

OR

With Consult
(1) Turn ignition switch "ON".




(2) Perform "EGRC SOLENOID VALVE" in "ACTIVE TEST" mode with CONSULT and check the operating sound, according to ON/OFF switching.

OR

No Tools
(1) Turn ignition switch "ON".




(2) Check operating sound of the solenoid valve when disconnecting and reconnecting harness connector.

EC-EGRC/V-01 EGRC-Solenoid Valve (DTC P1400):




WIRING DIAGRAM




DIAGNOSTIC PROCEDURE

COMPONENT INSPECTION







Check air passage continuity.
If NG, replace solenoid valve.