Operation CHARM: Car repair manuals for everyone.

DTC 0307




ON BOARD DIAGNOSIS LOGIC
* The closed loop control has the one trip detection logic.

OVERALL FUNCTION CHECK
This procedure can be used for checking the overall function of the closed loop control. During this check, a DTC might not be confirmed.

With Consult
(1) Start engine and warm it up sufficiently.




(2) Select "MANU TRIG" and "HI SPEED" in "DATA MONITOR" mode with CONSULT, and select "FRO2MNTR-B1 (B2)".
(3) Hold engine speed at 2,000 rpm under no load during the following steps.
(4) Touch "RECORD" on CONSULT screen.
(5) Make sure of the following.
- "FR O2 MNTR-B1 (B2)" in "DATA MONITOR" mode changes from "RICH" to "LEAN" to "RICH" 5 times in 10 seconds.
- 5 times (cycles) are counted as shown below:

cycle | 1 | 2 | 3 | 4 |

FR O2 MNTR-B1(B2) R-L-R-L-R-L-R-L-R-L-R

R = "FR O2 MNTR-B1(B2)", "RICH"
L = "FR O2 MNTR-B1(B2)", "LEAN"

OR

Without Consult
(1) Start engine and warm it up sufficiently.
(2) Make sure that malfunction indicator lamp goes on more than 5 times within 10 seconds while keeping at 2,000 rpm in Diagnostic Test Mode II (Front heated oxygen sensor monitor).

DIAGNOSTIC PROCEDURE

For right bank
Refer to TROUBLE DIAGNOSIS FOR DTC P0130 (0503).
Refer to TROUBLE DIAGNOSIS FOR DTC P0135 (0901).

For left bank
Refer to TROUBLE DIAGNOSIS FOR DTC P0150 (0303).