DTC 0903
NOTE: If both DTC P0440 and P0446 are displayed, perform TROUBLE DIAGNOSIS FOR P0446 first.COMPONENT INSPECTION
The EVAP canister vent control valve is located on the EVAP canister and is used to seal the canister vent.
This solenoid (the EVAP canister vent control valve) responds to signals from the ECM.
When the ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal the vent is necessary for the on board diagnosis of other evaporative loss system components.
This solenoid valve is used only for diagnosis, and usually remains opened.
When the vent is closed, under normal purge conditions, the evaporative loss system is depressurized and allows "EVAP Control System (Small Leak)" diagnosis.
CONSULT REFERENCE VALUE IN DATA MONITOR MODE
ECM TERMINALS AND REFERENCE VALUE
Specification data are reference values and are measured between each terminal and (43) (ECCS ground).
ON BOARD DIAGNOSIS LOGIC
DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE
Perform "Procedure for malfunction A". If the DTC cannot be confirmed, perform "Procedure for malfunction B".
Procedure for Malfunction A
With Consult
(1) Turn ignition switch "ON".
(2) Select "DATA MONITOR" mode with CONSULT. Start engine and wait at least 5 seconds.
OR
With GST
(1) Start engine and wait at least 5 seconds.
(2) Select "MODE 3" with GST.
OR
Without Consult
(1) Start engine and wait at least 5 seconds.
(2) Turn ignition switch "OFF", wait at least 7 seconds and then turn "ON".
(3) Perform "Diagnostic Test Mode II (Self-diagnostic results)" with ECM.
OVERALL FUNCTION CHECK
Use this procedure to check the overall function of the EVAP canister vent control valve circuit. During this check, a DTC might not be confirmed.
Procedure for Malfunction B
With Consult
(1) Remove EVAP canister vent control valve from EVAP canister and disconnect hoses from the valve.
(2) Check air passage continuity.
Condition / Air passage continuity between (A) and (B)
12V direct current supply between terminals / No
No supply / Yes
DIAGNOSTIC PROCEDURE
COMPONENT INSPECTION
EVAP Canister Vent Control Valve
Check air passage continuity.
Condition / Air passage continuity between (A) and (B)
12V direct current supply between terminals / No
No supply / Yes
If NG, clean valve using air blower or replace as necessary.
EVAP Control System Pressure Sensor
1. Remove EVAP control system pressure sensor with its harness connector connected.
2. Remove hose from EVAP control system pressure sensor.
3. Use pump to apply vacuum and pressure to EVAP control system pressure sensor as shown in figure.
4. Check output voltage between terminal (2) and engine ground.
Pressure (Relative to atmospheric pressure) / Voltage (V)
0 kPa (0 mmHg, 0 inHg) / 3.0 - 3.6
-9.3 kPa (-70 mmHg, -2.76 inHg) / 0.4 - 0.6
CAUTION: Always calibrate the vacuum pump gauge when using it.
5. If NG, replace EVAP control system pressure sensor.