DTC 0807
SYSTEM DESCRIPTION
This system controls the vacuum signal applied to the EVAP canister purge control valve. When the ECM detects any of the following conditions, current does not flow through the EVAP canister purge control solenoid valve.
The solenoid valve cuts the vacuum signal so that the EVAP canister purge control valve remains closed.
- Start switch "ON"
- Closed throttle position
- Low or high engine coolant temperature
- During deceleration
- Engine stopped
COMPONENT DESCRIPTION
EVAP canister purge control solenoid valve
The EVAP canister purge control solenoid valve responds to signals from the ECM. When the ECM sends an OFF signal, the vacuum signal (from the intake manifold to the EVAP canister purge control valve) is cut.
When the ECM sends an ON (ground) signal, the vacuum signal passes through the EVAP canister purge control solenoid valve. The signal then reaches the EVAP canister purge control valve.
EVAP canister purge control valve
When the vacuum signal is cut by EVAP canister purge control solenoid valve, EVAP canister purge control valve shuts off the EVAP purge line.
EVAPORATIVE EMISSION SYSTEM DIAGRAM
CONSULT REFERENCE VALUE IN DATA MONITOR MODE
Specification data are reference values.
ECM TERMINALS AND REFERENCE VALUE
Specification data are reference values, and are measured between each terminal and (25) (ECCS ground).
ON BOARD DIAGNOSIS LOGIC
DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE
NOTE: If "DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE" has been previously conducted, always turn ignition switch "OFF" and wait at least 5 seconds before conducting the next test.
Procedure for malfunction A
Without Scan Tools
1) Turn ignition switch "ON" and wait at least 5 seconds.
2) Turn ignition switch "OFF", wait at least 5 seconds and then turn "ON".
3) Perform "Diagnostic Test Mode II (Self-diagnostic results)" with ECM.
Electrical Diagrams
Circuit Connectors
DIAGNOSTIC PROCEDURE
COMPONENT INSPECTION
EVAP canister purge control solenoid valve
Check air passage continuity.
If NG, replace solenoid valve.