Meter/Gauges Operation and Odo/Trip Meter
SELF-DIAGNOSIS FUNCTION- Odo/trip meter (board computer) segment operation can be checked in self-diagnosis mode.
- Meters/gauges can be checked in self-diagnosis mode.
HOW TO ALTERNATE DIAGNOSIS MODE
1. Turn the ignition switch ON, and switch the odometer/trip meter to "trip A" or "trip B".
NOTE: If the diagnosis function is activated with the trip meter A displayed, the mileage on the trip meter A will indicate 000.0 miles, but the actual trip mileage will be retained. (Trip B operates the same way).
2. Turn the ignition switch OFF.
3. While pushing the odo/trip meter switch, turn the ignition switch ON again.
4. Check that the trip meter displays
5. Push the odo/trip meter switch at least 7 times within 7 seconds.
6. All the segments on the odo/trip meter illuminate, and simultaneously the low-fuel warning lamp indicator illuminates. At this time, the unified meter control unit is turned to diagnosis mode.
NOTE: If any of the segments is not displayed, replace the combination meter.
7. Push the odo/trip meter switch. Each meter/gauge should indicate as shown in the figure while pushing odo/trip meter switch (at this time, the low-fuel warning lamp goes off).
How to Proceed With Trouble Diagnosis
1. Confirm the trouble symptom or customer complaint.
2. Perform diagnosis according to diagnosis flow. Refer to "Diagnosis Flow"
3. According to the trouble diagnosis chart, repair or replace the cause of the trouble symptom. Refer to "Trouble Diagnosis Chart by Symptom"
4. Does the meter operate normally? Yes: Go to 5. No: Go to 2.
5. INSPECTION END.